S792Nutrient: Nutrient analyses were conducted by Tom Oswald under the supervision of R. E. Turner
S792Pigment: The Turner Designs model 10 fluorometer was calibrated for chlorophyll a against a chemical supply house chlorophyll a standard measured on a spectrophotometer yearly (or more frequently if needed). During the cruise, the Fluorometer was blanked and calibrated daily in accordance with Turner Designs recommended procedures. Chlorophyll concentrations were supervised and quality controlled by Nancy Rabalais.
S792Seabird: Temperature, dissolved oxygen, percent oxygen saturation, conductivity, salinity, density, percent light transmission, fluorescence and depth were acquired with a SeaBird 911 CTD system that was used to obtain water column profiles at all stations.
Oxygen concentration determinations, upper and lower end, were made prior to the cruise by the LUMCON CTD technician and entered into the SeaSoft configuration file. Winkler oxygen titrations were conducted during the cruise. A regression equation developed from Winkler titrations gave a strong, good relationship. A correction of the SeaBird oxygen data was not necessary.
Due to a delay in response time of the oxygen sensor, oxygen data were not aligned well with conductivity and temperature depths in this dataset. Downcast dissolved oxygen values probably related better to other parameters in 1 meter above the oxygen probe. Bottom dissolved oxygen values were equilibrated.
Oxygen data were omitted from the top of casts if concentrations indicated that the CTD oxygen probe was not equilibrated due to inadequate ""soak"" time or too fast a lowering speed. Oxygen data were removed from one or more depths at 6 of the 71 the stations sampled. Dissolved oxygen and percent oxygen saturation values were negative for two depths at Station A3.
Data reductions from the SeaBird were generated by Ben Cole and quality controlled by Nancy Rabalais.
S792Stns: Position coordinates were logged from RV Pelican’s Loran C. Station depths were logged from the ship’s fathometer.
S792SuspSed: Suspended sediment concentrations were supervised and quality controlled by Nancy Rabalais
N. Rabalais performed an additional procedure in quality-control/quality-assurance by evaluating relationships between the data in S792Hydrolab, S792Nutrient, S792Pigment, S792Seabird and S792Stns.